Customization: | Available |
---|---|
Warranty: | 1 Year |
Acid Tank Volume(L): | 500~4000L |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Procedure | Time | Temperature |
Water prewash | 3min~ 5min | 40ºC~ 50ºC |
Alkali wash | 5min~ 15min | 60ºC~ 80ºC |
Intermediate washing | 3min ~ 5min | 40ºC~50ºC |
Acid pickling | 5min~ 10min | 60ºC~ 80ºC |
Finally water washed | 3min~ 5min | 40ºC~50ºC |
Parameters / Model | RYG-0.5 | RYG-1 | RYG-2 | RYG-3 | RYG-4 | |
Acid tank volume(L) | 500 | 1000 | 2000 | 3000 | 4000 | |
Alkali tank volume(L) | 500 | 1000 | 2000 | 3000 | 4000 | |
Hot water tank volume(L) | 500 | 1000 | 2000 | 3000 | 4000 | |
Heating method | Coil, plate, tube heating, electric heat pipe heating | |||||
Pump |
Flow rate(m3/h) | 10 | 10 | 20 | 20 | 30 |
Pump head(m) | 24 | 24 | 36 | 36 | 36 | |
Power(kw) | 2.2 | 2.2 | 4.0 | 4.0 | 5.5 |