Customization: | Available |
---|---|
Certification: | ISO9001, CE |
Salt Rejection Rate: | 99.9% |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PSG series pure steam generator is the equipment which is manufactured purified steam by heating industrial steam. It is adopted the deion water as raw water. It is mainly used for pharmaceutical equipments and sterilization of all kinds of craft production line (pipeline and storage tank etc.)
Model Technical parameter |
Industrial steam pressure (MPa) |
Pure steam output (L/H) |
Industrial steam consumption (L/H) |
Raw water consumption (L/H) |
Power (kW) |
Overall size (mm) |
Weight (kg) |
PSG100 | 0.3 | ≥100 | 110 | 110 | 0.6 | 1100×390× 2100 | 175 |
PSG 200 | 0.3 | ≥200 | 220 | 220 | 0.6 | 1200×430× 2500 | 220 |
PSG 300 | 0.3 | ≥300 | 330 | 330 | 0.6 | 1350×500× 2630 | 300 |
PSG 400 | 0.3 | ≥400 | 440 | 440 | 0.6 | 1350×500× 2780 | 350 |
PSG 500 | 0.3 | ≥500 | 550 | 550 | 0.6 | 1600×700 ×2850 | 500 |
PSG 750 | 0.3 | ≥750 | 825 | 825 | 0.8 | 1600×700 ×3100 | 600 |
PSG 1000 | 0.3 | ≥1000 | 1100 | 1100 | 0.8 | 1900×770 ×3300 | 750 |
PSG 1500 | 0.3 | ≥1500 | 1650 | 1650 | 1.2 | 2000×850 ×3550 | 1000 |
PSG 2000 | 0.3 | ≥2000 | 2200 | 2200 | 1.6 | 2000×850× 3750 | 1200 |
The control way of PSG series pure steam generator, providing more choices among Manual, Instrument full automatic, Touch screen/PC etc. (Our company can customize design according to the requirements of customer). The differences of configuration between these three control ways are as follows:
Item | Manual | Instrument full automatic | Touch screen/PC |
Industrial steam control | Manual stop valve | Pressure reducing valve | PID Pneumatically regulating valve |
/ | / | Pressure transmitter | |
Raw water control | Manual diaphragm valve | PID Pneumatically regulating valve | PID Pneumatically regulating valve |
/ | / | Flow transmitter | |
Purified steam output control | Manual diaphragm valve | Manual diaphragm valve | Pneumatic diaphragm valve |
/ | / | Pressure transmitter | |
Excess distilled water drainage control | Magnetic valve | Pneumatically angle seat valve | Pneumatically angle seat valve |